View non-flash version
1994 Military Suppliers Guide Gibbs & Cox, Inc. Circle 59 on Reader Service Card Gibbs & Cox, Inc. is a multi-disci- plinary engineering firm having as its primary focus naval architecture and marine engineering. It is recog- nized worldwide for its work in the design of naval surface combatants and commercial ships, and is cur- rently engaged in the design of an advanced combat system frigate for Naval ships, fleet oilers, commercial containerships, tankers and dredges are successfully finding new ways to operate more efficiently at lower cost, by utilizing Tranter's unsurpassed plate-type heat exchanger technology. Schematics presented here illustrate typical ways they are doing it. Superchanger® plate and frame heat exchangers are used in a wide variety of shipboard applications—particularly for cooling main engine jacket water and cooling main engine lube oil with fresh water or sea- water; cooling the ship's central fresh water; cooling electronic equipment; or recovering heat from condensate. They are far more effi- cient than tubular systems, and provide heat transfer coefficients from two to five times greater than those achieved by shell and tube units. They also require 10% to 50% less deck space and weigh up to one-sixth less. Superchanger units can be equipped with titanium plates which offer the best resistance to corrosion and erosion when exposed to seawater. Intermixing or cross-contamination the Republic of China and sealift ships for the U.S. Gibbs & Cox, Inc. is headquartered in New York City with offices in Arlington, Va.; Brunswick, Maine; and Pascagoula, Miss. HomiltonJot Circle 60 on Reader Service Card HamiltonJ et's advanced waterjet of hot and cold liquids is virtually impossible. Low fouling rates reduce cleaning require- ments for Superchanger units, that are designed for easy maintenance. They can be cleaned-in-place by backflushing, or quickly disassembled by hand, cleaned and put back in operation. Platecoil® prime surface heat exchangers offer optimum temperature control. A Platecoil bank-in-tank unit provides wide interspaces for effectively passing solids while efficiently heating seawater containing oil from spills. Platecoil bayonet heaters provide a large amount of efficient primary heating surface in a single unit for maintaining desired temper- atures in storage tanks. These heaters help promote convection currents for better heat transfer rates and tank temperature uniformity. Platecoil suction heaters provide immediate heating for pumping oil out of tanks. Tranter plate-type heat exchangers can be supplied in full compliance with codes and specifications as required by the ABS; the U.S. Coast Guard; shock testing per MIL-S- Circle 323 on Reader Service Card propulsion systems meet the stan- dards of certifying authorities such as Lloyds and ABS, making them widely accepted by military and paramilitary organizations around the world. Applications include main propulsion for high speed pa- trol, riverine assault, RIB assault and rescue and other multi-mission craft, as well as wide use as a loiter/ boost propulsor in conjunction with 901C; vibration testing per MIL-STD-167-1; and ASME U stamp per Sec. VIII Div. 1. With over 50 years of heat transfer problem solving experience, Tranter is uniquely poised to answer your tough questions and solve your precise needs. Call us at (817) 723-7125. Better still, ask your local Tranter representative about our Heat Transfer PLATECOIL . SUPERCHANGER • FLEXOPLATE • KOLD-HOLO TRANTER, inc., Texas Division Old Burk Road • P.O. Box 2289 Wichita Falls TX 76307 • (817) 723-7125 TELEX: 73-4410 • FAX: (817) 723-5131 • MADEINU.SA ©1993 TRANTER, inc. 650101 Intergraph CAD graphic. other drives. With units for power inputs up to 3,000 kW, optimum propulsion options for vessels up to typically 197 feet (60 meters) long are available. Logistic services, including docu- mentation and training programs, are provided for all projects through an extensive global support network. Hollon Fluid Stroinors Circle 61 on Reader Service Card Hellan fluid strainers have been chosen by the Navy to replace du- plex strainers on all CG-47 cruisers to protect radar, sonar, GTC, pha- lanx, LPAC, etc. Hellan says its fluid strainers need little or no main- tenance; are self-contained, so sail- ors are not exposed to harmful de- bris or chemicals; weigh 60 to 70 percent what duplex strainers weigh; and can be cleaned in 30 seconds without disassembly. The company claims this translates into major cost savings. In the 18 months since Hellan strainers were installed on the CG-47s, there have reportedly been no complaints. Hellan fluid strainers are approved by ABS, U.S. Coast Guard and Navy. The Navy is reportedly consider- ing Hellan strainers in place of du- plex strainers, starting with Flight IIA of DDG-51 destroyers. Both the Navy and private shipyards are also considering Hellan strainers for use on other Navy class ships. Hl-lbst Laboratories, Inc. Circle 62 on Reader Service Card Hi-Test Laboratories, Inc. pro- vides test and evaluation services to commercial and military clients in the areas of shock, noise, vibration and ship survivability with special emphasis in underwater explosion technology (UNDEX). Tests are con- ducted in accordance with applicable military specifications, i.e., MIL-S- 901/MIL-STD-167/MIL-STD-740, etc. The company offers state-of- the-art instrumentation, high-speed photography and video coverage, certified instrument calibration, pro- cedure preparation, fixture design and fabrication. Qualified quality assurance and welding procedures are provided in all fabrication disci- plines. Certified welding personnel are qualified to applicable ASTM, AWS, and Military Specifications for various materials including HTS, HSLA, HY-80, HY-100, etc. Hi-Test is a major manufacturer and dis- tributor of MIL-spec shock and vi- bration test machines, as well as How to Operate More Efficiently At Lower Cost With Tranter Plate-type Heat Exchangers HEAT RECOVERY FROM CONDENSATE CONDENSATE DESALINATION UNIT HEATING RECOVERED OIL STEAM SEAWATER COOLING ELECTRONIC GEAR ^ „ HEATED TANK FOR BANK RECOVERED OIL SPILLS i : * - • SEAWATER SUPERCHANGER UNIT FRESH WATER SUPEHSHANGER HEATING SHIP'S UNIT WATER SERVICE COOLING MAIN ENGINE WATER RADAR CENTRAL FRESH WATER COOLER SEAWATER --SEAWATER DESALINATION UNIT SEAWATER SUPERCHANGER/ OR FRESH UNIT WATER COOLING MAIN ENGINE LUBE OIL SUPERCHANGER UNIT FRESH WATER STORAGE TANK TO VARIOUS USE POINTS SEAWATER OR FRESH WATER SUPERCHANGER UNIT 56 Maritime Reporter/Engineering News