View non-flash version
DIESEL GENERATOR SETS 250 KW DIESEL GENERATOR SET ENGINE: Enterprise 12 x 15 DSG-6—6 cyl.—450 RPM crank No. 50J. GENERATOR: Westinghouse 250 KW—120 /240 DC—1040 amps—450 RPM. Typical serial No. 3S- 1 OP - 913. Complete with switch gear. EMERGENCY GENERATOR SUPERIOR 75KW 120/240 VOLT D.C. DIESEL GENERATOR SET With switchgear. ENGINE: Radiator cooled Superior GBD-8—6 cylinder—1200 RPM GENERATOR: Electric Machinery Co.—120/240 volts DC—316 amps—1200 RPM—stab, shunt. UNUSED 10 KW SUPERIOR DIESEL GENERATOR SET GENERATOR: Delco 10 KW — 120 VDC — 83.3 amps— 1200 RPM. ENGINE: Superi- or diesel—2 cyl.—4'Ax5% •— 15 HP — heat exchanger cooled. 500 KW— 120/240 VOLT DC DIESEL GENERATOR SET EQUAL TO NEW GENERATOR: Allis Chalmers—Compound wound. Has Class "A" insulation. Output 500 KW—120/240 volts DC—2080 amperes—720 RPM—drip-proof—self-cool- ing. Ambient 50°C—temperature rise 40°C. ENGINE: Model GM 8-278—2-cycle—Vee type—8Vi"xlO'/2"— air starting—720 RPM. Complete with switchgear. Condition very good. Stilll aboard naval vessel. Has Ross shell & tube type lube oil & raw coolers—temp, control valve—shock mounts. 400 KW WESTINGHOUSE TURBO GEN SETS FOR BETH. SPARROWS PT. HULLS 400 TO 4500; QUINCY HULLS 1600 400 KW (500 KVA)—80% PF—1200 RPM—450/3/ 60. TURBINE: 585 lbs—840'TT—28'/2" vacuum— 9018 RPM—serial 10A4462-3 & 10A4462-4. GEAR: 9018/1200 RPM. A.C. GENERATOR: 500 KVA—400 KW—450 volts—641 amps—80%PF—3 phase 60 cycle—1200 RPM—CR 40*—excitation amps 41— excitation voltage 120. Instruction book 5442. Switch- gear available. 300 KW DIESEL GENERATOR SET ENGINE: G.M. 6-278—6-cylinder—2 cycle— 83/4"xl0Vi"—750 RPM—with oil and water Ross Shell and Tube Heat Exchangers, instru- ment panel, pyrometer, etc. Vibro Isolators. GENERATOR: G.E. 300 KW—120/240 volts DC —1250 amps—shunt wound—continuous over- load rating 375 KW—2 hours—55° Weight of unit approximately 26,000 pounds. Complete with shock mounts. Unit 13' 2" long, 64" wide, 8' high. TURBO GENERATOR SETS UNUSED 300 KW—240 VOLT DC WESTINGHOUSE LOW-PRESSURE TURBO-GENERATOR SET GENERATOR: 300 KW—240 VDC—1250 amps— 1200 RPM. GEAR: 5286/1200—frame 6x15—serial 10A-2612-4. TURBINE: Frame C-325—225 PSI—397° TF—5286 RPM—Serial 10-A-2611-4. Wt. 16,700 lbs. —complete in original factory crate. WESTINGHOUSE 440/3/60 200 KW UNIT GENERATOR: Westinghouse 200 KW—250 KVA— 450/3/60—1200 RPM—80% PF—with 40 KW—120 VDC on same shaft. GEAR: 9989/1200 RPM—double helical. TURBINE: Westinghouse — 540 PSI—super- heat 322°F. Test 930 PSI 800°TT. Also operate 615 PSI—850°TT. 1250 KW G.E. 10-STAGE TURBO GENERATOR SET TURBINE: 525—615 PSI—850°TT—7938 RPM—10- stage—type FSN. GEAR: Single helix—7938/3600. GENERATOR: 1250 KW—450/3/60/3600—.80 PF— type ATB with surface air cooler. Overload 25%— 2 hours—1563 KW. UNUSED 300 KW G.E. 120/240 VOLT DC ^ TURBO-GENERATOR SET 10 GENERATOR: 300 KW—120/240 VDC—1250 amps— 1200 RPM. REDUCTION GEAR: 8.344:1 — 10012/ 1200 RPM—type S-182. TURBINE: DOR418N—449 H.P.—10012 RPM—working pressure 180/220 PSIG. 11 12 13 14 15 6 EQUAL-TO-NEW LATE TYPE 500 KW SHIPS SERVICE TURBO GENERATORS 1962—DeLaval. Very lit- tle use. Completely pre- served with rotors and diaphragms crated sepa- rately. TURBINE: DeLaval —585 PSI — 840°TT—6- stage—6391 RPM—class CD — Also suitable 440 lbs.—740°TT—25" vac. GEAR: 6391/1200 RPM. GENERATOR: Allis-Chalmers—450/3/60. Totally enclosed, with static exciter and voltage regulator system. Weight 17,665 lbs. Complete with latest dead front switch gear. Also available are the con- densers, circulating and condenser pumps. All very up-to-date, compact construction. Turbines will easily handle 600 KW if up-grading is desired. AP2 VICTORY WORTHINGTON- MOORE CROCKER-WHEELER 300 KW UNIT TURBINE: 440 PSI—740°TT—28V4" vacuum—type S4 — 5-stage — 6097 RPM — serial 7547 & 7548. GEAR: 6097/1200. GENERATOR: 300 KW—120/240 volts DC—1250 amps—compound wound—973643— 999759. Armature flange 8'A"; B.C. 7"—12 holes. ALSO NEW ARMATURES IN STOCK & 300 KW SHUNT ARMATURES. VICTORY 300 KW WESTINGHOUSE TURBO GENERATOR SET 440# —740°F —5930 RPM — 2A-9794-15-16-17 — coupling non-recessed on steam end of pinion—534". GENERATOR: Westinghouse 300 KW—120/240 DC -1200 RPM ~ "" ' 1250 amps- :.B. 208.4. UNUSED CROCKER-WHEELER S00 KW GENERATOR ENDS ONLY 120/240 VOLTS D.C.—1200 R.P.M. FORMERLY USED WITH WORTH INGTON- MOORE TURBINES & GEARS Upgraded by U.S. Navy—rewound in glass. Generator Frame and Armature—Marine 500 KW type 3-1200-—dripproof enclosure—base mount. Modified from Crocker-Wheeler generator frame 152HD —240/120 volts DC —2083/521 amps— 1200 RPM. Ambient temperatures 50°C. APPLICA- TION: For C-4-SA1; C4-SA-3; T-AP-134 vessels, using Worthington-Moore Turbine—Form S-6 and generator Form 14x10. No pedestal bearing. FOR USE ON NEWPORT NEWS VESSELS—HULLS 480 to 541 CLASS—SIMILAR TO ESSO LIMA CLASS 400 KW WESTINGHOUSE TURBO GENERATOR TURBINE 835 lbs—840°TT—9018 RPM—instr. book 1430 CI—serial 5A-7090-7 and 5A-7090-8—6-stage. REDUCTION GEAR 9018/1200 RPM A.C. GENERATOR 400 KW—450/3/60/1200 RPM—rise 40°C—100% and 58°C—125%. In book 5442. Serial 3S-35P792 and 4S-35P792. 5.5 KW—125 volt: 44 amps. EXCITER —shunt wound—frame 6-83— ,^ound the Main Office: (301 TURBINES & ROTORS 16 17 BETH CLASS SERIES TURBINE—13,600 H.P. SPARROWS POINT 4400-4500 SERIES QUINCY 1600 SERIES HULLS 28,000 GT/29,000 GT ONE H.P. TURBINE—BUILT 1949 600 LBS.—860°F—SHAFT HORSEPOWER 6150 AT 4773 RPM—SERIAL #1630-H-4 6690 H.P. HIGH PRESSURE 7-STAGE TURBINE ORIGINALLY BUILT FOR ESSO CHRISTOBOL—NEWPORT NEWS 6690 H.P. AT 7862 RPM PRESSURE 835 LBS GAUGE TEMP. 840°F—SERIAL 83343 FOR EMERGENCY USE In an emergency, this HP turbine could substitute for Newport News built HP with piping and foundation change. 18 19 STAGE WESTINGHOUSE H.P. ROTOR FOR AP2 VICTORY Reconditioned — balanced— with ABS. Serial 4A-2079— type B — 19 stage reaction blades. Excellent — just out of shop. 13" Flange diameter with 14 bolts. 19 8500 H.P. G.E. TURBINE G.E. instruction book GEM 6263—from ex-Navy Victory. L.P. — 8-stage—3509 RPM—77943 H.P.—8-stage—6159 RPM—77942. WILL INTERCHANGE WITH INGALLS C3 HULL—442 CLASS AND SUN-BUILT C4 VESSELS 20 NEW LP. BLADB RINGS for largo 8S00 H.P. Victory Joshua Handy Westinghouse 21 SPECIAL! 1 WESTINGHOUSE COMPLETE T-2 MAIN TURBINE PROFILE (UNSHROUDED) 6600 HP—435 PSI—750°F 28" VAC.—3720 RPM Instruction Book 6893—Serial #2A-9361-21. The turbine rotor blades, stationary blading, diaphragms and nozzles are all in unusually good condition. IMMEDIATE DELIVERY—WITH ABS